Call Us

(951) 777-9965

Commercial electrical problems can shut down your business, damage equipment, and create serious safety hazards for employees and customers. The eight issues below are the ones Riverside business owners most often overlook until something goes wrong. Catching them early is almost always cheaper and safer than waiting for a failure.

Each problem on this list has a clear warning sign and a straightforward next step. If you recognize any of them at your property, treat it as urgent, not a “we’ll get to it” item.

commercial electrical problems

1. Frequently Tripping Circuit Breakers

A breaker that trips once in a while is doing its job. A breaker that trips repeatedly is telling you the circuit is overloaded, there’s a short circuit somewhere, or the breaker itself is failing. In a commercial setting, repeated trips often mean the electrical load has grown beyond what the original wiring was designed to handle.

Riverside businesses that have added equipment over the years, such as additional HVAC units, commercial kitchen appliances, or server racks, are especially prone to this. The Inland Empire’s hot summers push HVAC systems hard, and that extra draw can push older panels past their limits.

2. Flickering or Dimming Lights

Flickering lights in a commercial space are rarely just a nuisance. They usually point to a loose connection, a failing ballast or driver in older fixtures, voltage fluctuations, or an overloaded circuit. Any of these can worsen over time and create a fire or shock hazard.

If the flickering happens when large equipment cycles on (a compressor, elevator, or HVAC unit), that’s a voltage drop issue. If it’s constant and isolated to one area, suspect a loose wire or a failing fixture.

3. Outdated or Undersized Electrical Panel

Many commercial buildings in Riverside, particularly those built before the 1990s, are running on panels that were never designed for today’s electrical loads. An undersized panel can’t safely distribute power to modern equipment, and an outdated one may lack the arc-fault and ground-fault protection now required by the National Electrical Code.

According to the National Electrical Code (NEC), commercial installations must meet current code requirements when significant modifications are made. A panel that was adequate in 1985 may be a code violation today if your business has expanded.

3. Outdated or Undersized Electrical Panel — commercial electrical problems

4. Burning Smells or Scorch Marks Near Outlets and Panels

A burning smell or visible scorch marks around an outlet, switch, or panel is an emergency, not a maintenance item. These signs almost always mean arcing is occurring, which is one of the leading causes of electrical fires in commercial buildings. The U.S. Consumer Product Safety Commission notes that arc faults are responsible for thousands of fires annually in the United States.

A scorch mark around an outlet is your building telling you a fire almost happened there. Don’t wait to find out what happens next.

5. Insufficient or Outdated Outlets

Running power strips and extension cords as a permanent solution is one of the most common electrical hazards in commercial spaces. It’s also a code violation in many configurations. The National Electrical Code prohibits using extension cords as a substitute for permanent wiring in commercial occupancies.

Older Riverside commercial buildings often have far fewer outlets than a modern business needs. Retail spaces, offices, and restaurants that have grown their equipment footprint frequently end up daisy-chaining power strips, which overloads circuits and creates a fire risk.

6. Ground Fault and GFCI Issues

Ground fault circuit interrupters (GFCIs) are required by code in commercial areas where water is present, including restrooms, kitchens, break rooms, and outdoor areas. A GFCI that won’t reset, trips constantly, or was never installed in a wet location is a serious shock hazard for employees and customers.

The Occupational Safety and Health Administration (OSHA) requires GFCI protection for construction sites and many commercial environments under 29 CFR 1926.404. State and local codes in California often go further, requiring GFCI protection in additional locations beyond the federal baseline.

6. Ground Fault and GFCI Issues — commercial electrical problems

7. Power Outages or Partial Outages in One Area

A partial outage, where one section of your building loses power while the rest stays on, is a sign of a failed breaker, a wiring fault, or a problem at the panel. In a commercial setting, a partial outage can halt operations, damage equipment mid-cycle, and create liability if it affects safety systems like emergency lighting.

Riverside’s summer heat puts extra stress on electrical infrastructure. High ambient temperatures can accelerate insulation breakdown and cause connections to loosen over time, both of which can trigger partial outages.

8. No Plan for EV Charging Infrastructure

This one isn’t a failure yet, but it will be soon for many Riverside businesses. California’s push toward electric vehicles means your employees, customers, and fleet vehicles will increasingly need charging access on-site. Commercial properties without EV charging infrastructure are already losing tenants and customers to competitors who have it.

Installing commercial EV chargers (Level 2 or DC fast chargers) requires dedicated circuits, proper panel capacity, and permits from the City of Riverside. This is not a DIY project, and retrofitting a building that wasn’t designed for it takes planning. If you’re curious what a commercial EV installation looks like in practice, take a look at our EV Charger Installation Project page.

Every one of these eight problems shares a common thread: they start small and get expensive fast. A tripping breaker today can become a panel fire next year. A missing GFCI can become a worker’s compensation claim. Addressing commercial electrical issues early, before they escalate, is almost always the lower-cost and lower-risk path. If you spotted more than one of these problems at your Riverside business, that’s a strong signal to schedule a professional electrical assessment sooner rather than later.

Ready to get your commercial electrical system evaluated? Request a quote from Golden Power Electric, or call us at (951) 777-9965 to talk through what your building needs.

FAQs

How often should a commercial building’s electrical system be inspected?

Most commercial buildings benefit from a professional electrical inspection every 3 to 5 years, or any time major equipment is added, the building changes use, or you notice warning signs like tripping breakers or flickering lights. High-demand facilities like restaurants or manufacturing spaces may need more frequent checks.

What are the most common causes of electrical fires in commercial buildings?

Arc faults from damaged or loose wiring are a leading cause, followed by overloaded circuits, outdated panels, and improper use of extension cords as permanent wiring. Regular inspections and arc-fault circuit interrupter (AFCI) protection significantly reduce these risks in commercial occupancies.

Is it safe to keep resetting a tripping breaker at my business?

Resetting a breaker once to restore power is fine. Resetting the same breaker repeatedly without finding the cause is not safe. Repeated tripping means the circuit is overloaded, there’s a fault in the wiring, or the breaker itself is failing. Each of those scenarios needs a professional diagnosis, not another reset.

Do commercial buildings in Riverside need GFCI outlets?

Yes. California’s electrical code, which adopts and often exceeds the National Electrical Code, requires GFCI protection in commercial restrooms, kitchens, break rooms, outdoor areas, and anywhere outlets are within 6 feet of a water source. Missing GFCI protection is both a code violation and a genuine shock hazard.

What’s the difference between a partial outage and a full power outage at a business?

A full outage means the building has no power, often caused by a utility issue or a main breaker failure. A partial outage means some circuits or zones are dead while others work, which usually points to a tripped or failed breaker, a wiring fault, or a problem at the panel that needs an electrician’s diagnosis.

How do I know if my commercial panel needs to be upgraded?

Key signs include breakers that trip frequently, a panel that feels warm, fuses instead of breakers, breakers that won’t hold their position, or a panel that’s more than 25 to 30 years old. If your business has added significant equipment since the panel was installed, a load assessment is a smart first step.

Can my Riverside business get a tax incentive for installing EV chargers?

Federal tax credits for commercial EV charging equipment have been available under the Alternative Fuel Vehicle Refueling Property Credit (IRS Form 8911). California also has utility and state programs that may offset installation costs. A tax professional can confirm current eligibility, and an electrician can assess what your building’s panel can support before you apply.

What should I do if I smell burning near an electrical panel at my business?

Treat it as an emergency. A burning smell near a panel often means arcing or overheating is occurring inside. Turn off the main breaker if it’s safe to do so, evacuate the area, and call a licensed electrician immediately. Do not ignore the smell or assume it will go away on its own.